Measurement and MRV · Greenhouse experiments

Can you monitor leachate EC and TA with a €13 sensor in ERW experiments? Yes! We tested it.

·

On this page 10 sections

As a side experiment of our current ERW greenhouse experiment (methods paper, blog article), we installed cheap EC sensors into the leachate collection tanks of 24 pots. Inspired by the empirical relationship observed by Amann and Hartmann (2022), and the encouraging results we observed in our first greenhouse experiment, we wanted to see if we could reduce the number of manual EC and TA measurements by substituting them with EC sensor data, as this could potentially lower monitoring costs.

These cheap (€13) sensors are located at the bottoms of the tanks that collect the pot's drainage water. Here we compare these sensor-based EC measurements with our high precision in situ leachate EC measurements using a WTW multi-parameter analyser (MultiLine® Multi 3630 IDS) and its TetraCon® 925 EC sensor (SD ± 5 µS/cm) every 6-8 weeks. After one calibration against in situ values, 67 of 76 sensor readings were within 10 % of the in situ measurements. The sensors have clear limits: they show nothing below 100 µS/cm, they have no built-in temperature correction, and three of 24 sensors died within eight months. Converting continuous EC data into alkalinity estimates works when the EC-TA ratio is calibrated for every pot at least at every second sampling, and the first 100 days after set-up are left out. Leaving out every second alkalinity titration and filling the gap from the sensor's EC measurement changed a pot's cumulative alkalinity export by only around 3 %, suggesting that measurement costs could be reduced without substantially compromising the accuracy of alkalinity export estimates.

Drawing of a greenhouse pot in cross-section above its leachate tank: grass on top, soil with a CO₂ sensor and a tea bag, a layer of filter sand at the bottom, water dripping into the tank, and an EC probe lying at the bottom of the tank, wired to a small sensor board and a reader outside
Figure 1: A pot of the experiment and its leachate tank (schematic). The irrigation water drains through the soil into the tank below. The EC/TDS sensor (12) is lying at the bottom of the leachate tank, fixed with a glass weight, and its board and the minicomputer that reads it sit outside the tank.

Every data point on leachate chemistry in our greenhouse is manual work. Every six to eight weeks, a team of several people spends several days (!) in the greenhouse: we empty the leachate tank of each of the 450 pots, measure the volume and take a sub sample for in situ measurements like pH, electrical conductivity (EC), O2 concentration and saturation and do a titration for total alkalinity (TA). So far that adds up to more than 4,400 analysed samples.

EC is the cheapest of these measurements, and one of the most useful. Our first greenhouse experiment showed that it tracks alkalinity closely enough to stand in for many titrations (see the MRV Proxies for ERW series and the TA/EC report). Back in 2024 we noted that “water EC sensors in leachate tanks could be an option to reduce our lab workload”, and we assumed that such sensors would have to be more accurate, and therefore more expensive, than the soil probes we had tested (Could soil EC sensors or leachate EC measurements be used to monitor enhanced rock weathering?). This side experiment puts that idea to the test.

What a sensor in the tank could take off our hands

Of the manual steps involved in a sampling event, the titration is the one that takes the most time. The idea here is to use a cheap sensor to replace alkalinity titrations for some of the sampling rounds, and convert EC data into TA data, which we showed to be possible. A sensor also delivers something that manual sampling cannot: while manual sampling provides only a snapshot at each sampling event, our sensor reports EC every 10 minutes, offering much greater temporal resolution.

We have tried this before, with sensors buried in the soil of our XXL lysimeters. A soil EC sensor at 60 cm depth tracked leachate EC at r = 0.70, and soil moisture directly affected the reading (Can a buried EC sensor stand in for lab alkalinity?). A sensor in the tank has an easier job: it sits in the leachate water itself.

What makes this sensor-based test worth reporting is the amount of data behind it. The sensors delivered 740,700 data points through our data pipeline over nine months, each representing the average of ten raw measurements to reduce noise (7.4 million raw measurements in total). We can check them against 111 manual measurements of the same leachate. To assess the relationship between EC and alkalinity, we use the 107 alkalinity titrations of the same leachate in the 22 pots whose leachate is concentrated enough for the sensor. This comes on top of the 3,794 leachate samples from our first greenhouse experiment and four years of soil sensor data from the XXL lysimeters. As far as we know, this represents an exceptionally large body of data for investigating such a seemingly simple question.

The set-up: a €13 sensor in the leachate tank

Since March 2026, 24 pots within our current greenhouse experiment (450 pots, running since June 2025) have a low-cost EC sensor installed in the tank that collects their leachate (Figure 1). Every pot drains into its own tank. The sensor sits in that same tank, so what it reads just before a sampling event is the same leachate water the sampling team measures during the sampling event.

On a black background: an orange M5 minicomputer with a small screen, wired to a blue sensor board, which connects by a long black cable to a white waterproof probe with two metal pins at its tip
Figure 2: The hardware of one pot. From left: the reader (an M5StickC Plus minicomputer), the sensor board, and the waterproof probe with its two pins, which hangs in the leachate.

The sensors report about 137 times per pot per day. From April to October 2026, the tanks were sampled five times, which gives 111 direct comparisons between a sensor and the in situ measurement of the sampling team.

Out of the box: the sensor is close to the in situ measurements, but it reads low in dilute leachate

For every pot and every sampling event, we compare two numbers: the median of the sensor readings in the 24 hours before the sampling day, and the in situ EC that the sampling team measured in the collected leachate.

Of the 111 comparisons, 97 have a sensor reading. 69 of these 97 are within 10 % of the sampling value and 87 are within 20 %. Half of them differ from the in situ sampling by less than 6 %. That is the sensor as it reports, with nothing but the one-point calibration we did before installation.

The errors are not random. The sensor reads low, with larger discrepancies at lower EC values: about 20 % lower than the in situ measurements at 300 µS/cm, 7 % lower at 600 µS/cm and 1 % lower at 1,200 µS/cm (Figure 3, left). The readings follow a straight line that does not pass through zero. This systematic underestimation can easily be corrected with some math.

Two scatter plots. Left: sensor EC against the EC measured at the sampling, 0 to 1,400 µS/cm; the points follow a calibration line just below the one-to-one line, with a few outliers and dead sensors at zero. Right: deviation of the sensor in percent at the four later samplings, mostly 0 to 20 % low as reported and mostly within 10 % after calibration
Figure 3: Left: EC measurements from the sensor in the tank (median of the 24 hours before the sampling day) against the in situ EC measured by the sampling team, for 111 comparisons in 24 pots; the line is the calibration fitted at the first sampling. Right: deviation from the in situ measurement at the four later samplings, both as reported (open symbols), and after an initial calibration (closed symbols; n = 76). The sensor reads low in dilute leachate EC; however one calibration brings 67 of 76 readings within 10 % of the in situ measurements.

In the other 14 comparisons, the sensor showed no signal at all. We will come back to those below.

One calibration against real leachate fixes most of the discrepancy

Our systematic error can be corrected, and here one initial calibration from a single sampling event was enough. We took the 19 comparisons from the first sampling event in April and fitted a straight line: sensor = 1.05 × WTW − 73. Then we applied that line, unchanged, to the four sampling events that followed.

The result: 67 of the 76 later readings are within 10 % of the in situ WTW measurements, and 74 are within 20 %. Without the calibration, only 52 of 76 sensor readings were within 10 % (Figure 3, right). Half of the calibrated readings are within 5 % of the WTW measurements.

Two things did not help improve the calibration:

Does this make the manual EC measurement redundant? Not quite. We would keep one hand-held reading at every sampling event, because of what the comparison catches:

What the sensor shows between two sampling events

Figure 4 shows the full record of all 24 pots, with the sampling values superimposed on top. Three things are invisible to a six- to eight-week sampling rhythm.

Grid of 24 small time series, one per pot (soil A, B or C, control or treated), March to November 2026: daily median of the sensor EC with its daily range, sampling values as dots and days without signal as red bars; most lines run between 300 and 1,300 µS/cm with sudden steps
Figure 4: EC of the leachate in the tank for all 24 pots, February to November 2026 (740,700 readings; line = median of the day, band = range of the day, dots = sampling values, red = days without signal). The sensor shows what happens between two samplings, including the empty tank after sampling.

The tank runs dry after every sampling. Once a tank is emptied, the sensor has no signal until leachate arrives. In half of the 75 cases, that took less than 18 hours, in a quarter of them greater than two days.

The reading follows day and night. Within one day, EC swings by about 15 % of its median value. The swing follows the temperature in the pot closely, at about 1.7 % per °C, which is close to the roughly 2 % per °C known for the conductivity of water. This is an artifact of the measurement and not chemistry. We therefore work with the median of each day. From one day to the next, that median typically changes by less than 2 %.

EC does not stand still between samplings. Some pots record a constant value for months. Others step up or down by several hundred µS/cm within a few days. Where a sampling followed such a step, the WTW confirmed the new value.

Where a €13 sensor stops being good enough

A quarter of all readings carry no signal: 7 % of readings come right after a sampling, when the tank is empty, 8 % from two pots with very dilute leachate, 3 % from sensors that died and 6 % from other gaps. Behind these numbers are four limits.

The sensor is blind in dilute leachate. Below about 100 µS/cm, the sensor shows nothing. In all 11 comparisons where the WTW measured between 28 and 76 µS/cm, the sensor read zero. This is not a niche case: of the 4,460 WTW EC values of the whole experiment, 11 % are below 100 µS/cm. At the upper end, we could test the sensor up to 1,360 µS/cm.

The sensor needs enough water. In three comparisons, the tank held less than 350 ml at the sampling, and the sensor read only 31 to 68 % of the WTW value. The concerning part is that it did not read zero. In June, several sensors showed 120 to 340 µS/cm for weeks and then jumped, within the same two days, to the EC value that the WTW confirmed a week later. We think these sensors were only partly covered by water, however we cannot prove this from the data.

The sensor has no temperature compensation. That explains the daily swing described above, and probably part of the drift between seasons.

Sensors die. Three of the 24 sensors stopped working after five, six and seven months respectively. Seven further units stopped sending data on 26 August, for reasons we do not know. We did not replace any of them, although we could have. The greenhouse is warm and humid, all our equipment there fails now and then, and a €13 sensor cannot be expected to last forever. After eight months, 14 of the 24 units still had a working sensor and a connection. This matches what four years of buried sensors taught us: sensors die, and you should plan for it.

From EC to alkalinity: the sensor does as well as the WTW

The measurement we would most like to make less frequently is the alkalinity titration. In our first greenhouse experiment, in situ EC could be used to stand in for part of the titrations on two conditions: 1) the ratio between alkalinity and EC is calibrated for every pot, and 2) the initial salt flush during the first weeks as the soil in the pot settles is left out (Part 3, Part 6, Part 7). To determine this EC-TA relationship, EC was measured using the in situ WTW sensor. The question here is narrower: does it still work when the EC measurement comes from the €13 sensor?

We tested this on 22 pots and their five sampling events from April to October 2026; in the other two pots the leachate EC is too dilute for the sensor. The estimate uses no in situ EC measurements at all. At a titrated sampling event, we note how much alkalinity is equivalent to one µS/cm of sensor EC for each given pot, typically about 10 µmol/l. At the next sampling event, we multiply the sensor reading by that number. The initial salt flush plays no role in this test, because the pots were nine months old when the sensors went in.

Summed up over the months, the estimate holds. MRV does not need every single value. It needs the alkalinity that a pot exports over time: concentration times leachate volume, added up over all sampling events. So we asked what would have happened if we had titrated only at every second sampling event and used the sensor estimate in between. Every pot allows two such alternations, which gives 44 cases. In 30 of them, the alkalinity export stayed within 5 % of the fully titrated value, and in 39 within 10 %. The typical difference was 3 % (Figure 5, right). With the EC from the in situ WTW measurements, it is 27 and 37 of 44. The €13 sensor does this job as well as the in situ WTW measurements.

A single estimate can be far off. In May, 17 of 21 estimates were within 10 % of the measured titration, from July on only 17 of 53 (Figure 5, left). With the in situ WTW measurements, it is 19 of 21 and again 17 of 53, so the sensor is not the weakest link. The EC-TA ratio itself changed: one µS/cm was equivalent to 11 to 12 µmol/l of alkalinity in April and May, to 7 µmol/l in July, and to about 10 µmol/l again at the last sampling. We do not yet know the cause. Our working theory is a lack of water: evapotranspiration is very high in summer, so even though we irrigate more, a smaller proportion of the water drains through the pot. These discrepancies have little influence on the cumulative alkalinity export, because leachate volumes were low at the time: the July sampling accounted for 12 % of the alkalinity export over this period, compared to 30 % at the last sampling event.

Two scatter plots. Left: alkalinity estimated from the sensor against titrated alkalinity, 0 to 17.5 mmol/l; May points lie near the one-to-one line, many July points far above it. Right: difference of the summed alkalinity export per pot with sensor EC against hand-held EC, in percent; most of the 44 points lie near zero
Figure 5: Sensor-derived alkalinity estimates in 22 pots, April to October 2026. Left: every estimate (sensor EC × the pot's alkalinity per unit of sensor EC at the previous sampling event), against the measured titration of the same sample. Right: alkalinity export summed up per pot, when every second titration is replaced by an EC-derived estimate, expressed as the difference from the fully titrated value, comparing the EC from the sensor with the EC from the in situ WTW measurements (44 cases). Individual estimates are less accurate in summer, but the cumulative estimates remain reliable, and the sensor performs as well as the in situ WTW measurements.

Two things limit this result:

What this means for MRV

Can sensor data replace manual measurements? For EC yes, for a part of the titrations yes, for the sampling event itself no. After one calibration, 67 of 76 sensor EC values were within 10 % of the in situ WTW measurements, replacing every second titration changed a pot's alkalinity export typically only by 3 %, and the sensor adds about 137 readings per pot and day; emptying the tank, measuring the volume, pH and all other analyses stay manual.

Up to half of the titrations could go. The same saving is possible using in situ EC measurements, as our earlier substitution test showed. What the sensor adds is an EC value that nobody has to measure, and a continuous EC record between sampling events. Sensor and reader together cost less than €30 per pot, an amount that does not buy much lab time and titration consumables.

Titrations remain the ground truth. Every EC-based TA estimate above needs a titration from the same pot that is at most one sampling event old, and it does not work in the first 100 days. As we wrote in 2024: one cannot start with EC measurements and rely on them alone.

The recipe we would follow today:

Limitations

The sensor test covers one greenhouse, three soils, 24 pots and nine months, with one type of sensor and one type of reader. A different sensor, a field lysimeter or a second winter may behave differently. The alkalinity result rests on 22 pots and one summer: with 22 other pots the typical difference could as well have come out at 2 % or at 5 %. The same test with the in situ measurements on 412 pots of the experiment gives 3 % for the same months, so the sensor pots are not a lucky draw.

Two further limits apply to any EC-based approach:

Read more

EC as a proxy for alkalinity, from our earlier work: